MIL --- PRF --- 51200D
any fasteners) by any wearer to allow a snug fit. The strap shall be capable of being detached
from the carrier case and re --- attached while the operator wears MOPP IV gear.
3.3.13.5 Resistance to water. The carrier case, with compartment fasteners in the closed
position and oriented upright, shall not absorb more than 90 grams of water when subjected to
the water repellency test in accordance with 4.4.10.1.
3.3.13.6 Resistance to fungus and mildew. Carrier case shall resist moderate and severe fun-
gus/mildew growth.
3.3.13.7 Strength. After water resistance test, the wetted carrier case shall be capable of
withstanding an overload condition of 5.0 pounds in every compartment and pocket without
causing stretching, breaking or tearing of the material in any of the compartments, between any
compartments, and around connecting straps or fasteners.
3.3.13.8 Physical attributes. The carrier case, when filled with all components, shall have no
sharp or protruding features which could damage MOPP IV gear.
3.3.13.9 Noise. The carrier case, when filled with all components, shall not produce a detect-
able rattling sound from a distance of 25 feet.
3.3.14 Forms. The soil, surface and liquid sample compartments shall each contain one gov-
ernment furnished, chemical/biological agent sample documentation form for recording back-
ground information.
3.3.15 Instruction cards. Instruction cards shall be printed on 3 x 5 inch (±1/2) waterproof
cards. The printing on the cards shall be black on light background. The minimum font size
shall be 10. The cards shall be joined by metal ring(s) to permit viewing. Printing may be on
both sides in sequential order so that the cards will not have to be reoriented by the operator in
order to read. The operator shall not be able to tear cards with fingers. The information to be
printed on the cards shall be as follows:
M34A1 Sampling Kit Instructions
Soil Sampling Procedures:
1. Locate and prepare your sampling target area and sample documentation.
2. Don the overgloves provided.
3. Open bags containing the scoop and sampling containers.
4. Scoop a thin layer of top soil (not more than 0.5 inch deep) from a small area into the sample container. Fill the
sample bottle to 3/4 of its volume.
5. Screw the cap on tightly. Place the sample bottle in a sealable plastic bag provided. Write identification informa-
tion on custody seal and apply custody seal over a rolled end section of the plastic bag.
9