MIL --- PRF --- 51200D
3.3 Functional and physical requirements of components.
3.3.1 Overgloves.
3.3.1.1 Chemical resistance. During sample collection, the overgloves shall provide a barri-
er to prevent cross contamination of the inner Mission Oriented Protective Posture (MOPP) IV
gloves by liquid or solid contaminants. The gloves shall be made of a material which resists
deterioration by organic solvents to an extent equal or greater than nitrile rubber.
3.3.1.2 Fit and coverage. Overgloves shall be flock --- lined and capable of fitting over MOPP
IV gloves, size large (NSN 8415 --- 01 --- 138 --- 2499), and shall be at least 12 inches in length.
3.3.1.3 Slip resistance. Overgloves shall have embossed gripping surfaces to resist slip.
3.3.1.4 Color. Overgloves shall be black in color or of a color that contributes to field camou-
flage (e.g. dark green, brown or tan).
3.3.2 Scoops.
3.3.2.1 Capacity. Each scoop shall be capable of collecting a soil sample and transferring the
collected sample to a sample container without spillage. The minimum container capacity of
the scoop shall be 65 milliliters. The size and shape of the scoop shall enable the end of the
barrel part of the scoop to fit inside the mouth of a sample container to prevent spillage.
3.3.2.2 Strength. The handle of the scoop shall not break or deform by more than 3/4 inch
when experiencing a 3 pound load. The barrel of the scoop shall not break.
3.3.3 Sample containers.
3.3.3.1 Capacity. Each sample container shall consist of a seal forming container with a ca-
pacity capable of holding a minimum of 3 ounces of water by volume. The container opening
shall be at least 1.75 inches in diameter minimum.
3.3.3.2 Transparency. The sample container shall be clear or translucent to permit the ready
determination that a sample is present in the container without opening the sample container.
3.3.3.3 Leak, permeation and chemical resistance. The sample container shall not allow
droplets or vapors of agent Mustard (HD) or Sarin (GB) to permeate through any of the con-
tainer materials or to escape from the enclosed container for at least 48 hours. (See 4.4.4.)
3.3.3.4 Snug fitting parts. If the container consists of a jar, cap, and gasket(s), the gasket(s)
shall not fall out of the cap during operation. Any caps shall be removable and replaceable by
hand without tools.