MIL --- PRF --- 51200D
3.3.6.2 Large bags.
3.3.6.2.1 Physical attributes. Each large bag for secondary back --- up containment of up to
three bagged sample containers shall have a self --- closing or self --- sealing mechanism and shall
measure no larger than 12 inches by 13 inches, and shall be colored to protect samples from light,
distinguish bag from others, and to contribute to field camouflage.
3.3.6.2.2 Strength. Each bag shall be capable of passing the load capacity tests described in 4.4.6.
The secondary containment bag shall not puncture or tear when a 3.0 pound load is placed inside the
bag.
3.3.6.2.3 Leak resistance. Without any external materials other than a single layer of labeling tape,
each bag shall be capable of being sealed by personnel in MOPP IV. Each bag shall prevent water
leakage when tested for leakage in accordance with 4.4.7.
3.3.6.3 Drawstring bags.
3.3.6.3.1 Operability. Each drawstring bag shall be a tertiary bag that is capable of storing at least
8 sample containers surrounded by primary and secondary bags.
3.3.6.3.2 Physical attributes. Each drawstring bag shall be at least 18 inches long and 12 inches
wide, and shall have a pull type draw- string closure incorporated in the bag opening. The draw- string
closure shall provide a secure means of closing the bag which precludes unintentional opening of the
bag. Each drawstring bag shall have at least one drawstring. Each drawstring shall be at least 24 inches
in length or circumference.
3.3.6.3.3 Strength. Each drawstring bag shall have a minimum load capacity of 15 pounds without
puncture or tear of the bag or breakage of the drawstring when tested in accordance with 4.4.8.
3.3.6.3.4 Resistance to water. Each bag shall not absorb more than 5 grams of water when tested in
accordance with 4.4.10.2.
3.3.7 Labeling tape.
3.3.7.1 Adhesion to materials. The labeling tape shall be a waterproof, self --- adhesive, pres-
sure --- sensitive tape capable of being removed from the roll and securely adhering to the kit's
bags and jars in temperatures ranging from --- 20°F to 120°F. An operator wearing MOPP IV
gloves and overgloves shall be capable of tearing off or cutting off sections of labeling tape. The
tape's top surface shall be capable of being permanently marked by the kit's marker in tempera-
tures ranging from --- 20°F to 120°F.
3.3.7.2 Size. Its width shall be 1.5 ± 0.25 inch and length of the roll shall be 200 to 500 inches.
The tape shall be of a size that fits inside a pocket or compartment of the carrier.
6
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business