MIL-PRF-62546C
TABLE IV. Verification methods.
Require-
Verifica-
Require-
Verifica-
Title
Title
ment
tion
ment
tion
Operating requirements
3.3
4.3.3
Radiated susceptibility
3.3.3.5.7
4.3.3.15
BITE
3.3.1
4.3.3.1
Interface requirements
3.4
4.3.4
Voltage characteristics
3.3.2
4.3.3.1
Electrical interface
3.4.1
4.3.4
FOV
3.3.3.1.1
4.3.3.2
Configuration
3.4.2
4.3.4
Small fire
3.3.3.1.2.1
4.3.3.3
Vehicle armor type
3.4.3
4.3.4
coding
Large fire
3.3.3.1.2.2 4.3.3.4
Ownership and support
3.5
4.3.5
Reliability
3.5.1
4.3.5
BITE characteristics
3.3.3.1.3
4.3.3.5
Dissimilar metals
3.5.2
4.3.5
Response time
3.3.3.1.4
4.3.3.6
Encapsulation
3.5.3
4.3.5
Penetration response
3.3.3.1.5
4.3.3.8
Safety
3.5.4
4.3.5
Radiation stimuli
3.3.3.2.1
4.3.3.7 -
Finish
3.5.5
4.3.5
4.3.3.7.15
Identification
3.5.6
4.3.5
Penetrating munitions
3.3.3.2.2
4.3.3.8
Environmental
3.6
4.3.6
Nuclear hardening
3.3.3.2.3
4.3.3.9
requirements
Slow growth pan-fire
3.3.3.2.4
4.3.3.10,
High temperature
3.6.1.1
4.3.6.1.1
4.3.3.10.1
Low temperature
3.6.1.2
4.3.6.1.2
Start-up
3.3.3.3
4.3.3.11
Temperature shock
3.6.1.3
4.3.6.1.3
Power
3.3.3.4
4.3.3.12
Vibration
3.6.2
4.3.6.2
Input voltage decay
3.3.3.4.1
4.3.3.13
Shock
3.6.3
4.3.6.3
Steady state voltage
3.3.3.4.2
4.3.3.14
Leakage
3.6.4
4.3.6.4
EMI
3.3.3.5
4.3.3.15
Water immersion
3.6.4.1
4.3.6.4.1
Conducted emissions
3.3.3.5.1,
4.3.3.15
Diesel fuel immersion
3.6.4.2
4.3.6.4.2
3.3.3.5.2
Water jet
3.6.4.3
4.3.6.4.3
Conducted susceptibility
3.3.3.5.3,
4.3.3.15
Salt fog
3.6.5
4.3.6.5
3.3.3.5.4,
Fungus
3.6.6
4.3.6.6
3.3.3.5.5
Sand and dust
3.6.7
4.3.6.7
Radiated emissions
3.3.3.5.6
4.3.3.15
Humidity
3.6.8
4.3.6.8
4.3.1 Verification alternatives. The manufacturer may propose alternative test methods,
techniques, or equipment, including the application of statistical process control, tool control, or
cost effective sampling procedures to verify performance. See the contract (see 6.2) for
alternatives that replace verification methods required by this specification.
4.3.2 Inspection conditions. Unless otherwise specified (see 6.2), all inspections shall be
conducted under the following conditions:
a. Air temperature: 23 ± 10 °C (73 ± 18 °F)
b. Barometric pressure: 725 (+50, -75) mm [28.5 (+2, -3) in.] of mercury (Hg)
c. Relative humidity: 50 ± 30 percent (%)
4.3.2.1 Test temperature stabilization. Tests shall be conducted after the test sample has
been allowed sufficient time for temperature stabilization. Test temperature stabilization is the
point at which the test sample will not vary in temperature more than 2 °C (3.6 °F) per hour.
11
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business