MIL-PRF-62546C
3.6.4 Leakage.
3.6.4.1 Water immersion. The OFSA shall meet the requirements of 3.6 and shall not
leak when immersed in water (4.3.6.4.1).
3.6.4.2 Diesel fuel immersion. The OFSA shall meet the requirements of 3.6 and shall
not leak when immersed in diesel fuel (4.3.6.4.2).
3.6.4.3 Water jet. The OFSA shall meet the requirements of 3.6 and shall not leak when
exposed to water jet cleaning (4.3.6.4.3).
3.6.5 Salt fog. The OFSA shall meet the requirements of 3.6 and shall show no evidence
of corrosion after prolonged exposure to a salt laden atmosphere (4.3.6.5).
3.6.6 Fungus. The OFSA shall meet the requirements of 3.6 following prolonged
exposure, in a non-operating mode, to an environment favorable to fungus growth (see 4.3.6.6).
3.6.7 Sand and dust. The OFSA shall meet the requirements of 3.6 after exposure to air
driven sand and dust (4.3.6.7).
3.6.8 Humidity. The OFSA shall meet the requirements of 3.6 when operated in a high
humidity environment (see 4.3.6.8).
4. VERIFICATION
4.1 Classification of inspections. The inspection requirements specified herein are
classified as follows:
a. First article inspection (see 4.1.1)
b. Conformance inspections (CI) (see 4.1.2)
4.1.1 First article inspection. First article inspection shall consist of all the examinations
and tests of this specification, as specified in table IV (see 6.3).
4.1.2 CI. CI shall include the examinations and tests listed in table IV as defined by the
contract (see 6.4).
4.2 Order of inspection. Perform tests in any order.
4.3 Verification methods. Acceptable verification methods shall include visual and
tactile inspection, functional manipulation, measurement, sample tests, full-scale demonstration
tests, simulation, modeling, engineering evaluation, component properties analysis, and
similarity to previously-approved or previously-qualified designs.